Nikon FE
Two needles. One of them is yours.
Two needles, one finder
A vertical speed scale down the left side, with the aperture read optically at the top
- The finder
- What it adds up to
- 1/250 the speed the camera will use
- Memory lock: push the self-timer lever toward the lens. The reading is held while you keep it there; recompose and release.
Fig. 1 · Deliberate one stop under; one stop over
Batteries, and what happens without them
Two 1.5 V silver-oxide cells power the meter and the electronic shutter
- The shutter fires at a mechanical 1/90 s whatever the dial is set to; B also works. Set the dial to M90 so the setting matches what you get. The meter does not work.
- 1/90 is half a stop from both 1/60 and 1/125 — hand-holdable with a standard lens.
- The shutter speed dial
Fig. 2 · Battery clip and lid · power check
Compensation, memory lock, self-timer
±2 EV in half stops · limited to −1 at ASA 3200–4000 and +1 at ASA 12
- +1 EV on the ring = half the ASA on the dial. Use one or the other, never both, and return the ring to 0 afterwards.
- Lift and turn the ring; set the dial by holding its lock
Fig. 3 · Top: ASA dial with its lock, compensation ring and scale, shutter dial, self-timer/memory lock
What you may put on the front
F bayonet, 1959 — and a coupling lever that folds out of the way
- Full function
- AI, AI-S and Series E couple directly. Most later autofocus Nikkors with an aperture ring work too, focused by hand. Open-aperture metering, both modes, nothing to think about.
- Works, with a ritual
- Press the coupling lever release and raise the meter coupling lever before mounting. Meter stopped down: hold the depth-of-field preview lever in while adjusting.
- Mechanical interference
- IX Nikkors and the deep pre-1960s fisheyes intrude far enough into the body to hit the mirror. Lenses with no aperture ring at all leave you with stop-down working only, and DX lenses throw a circle smaller than the frame.
- Flash
- Electronic flash: 1/125 down to 8 s, plus B and M90. Flashbulbs: 1/30 or slower. On AUTO with the SB-10 mounted and switched on, the camera sets 1/90 itself. No TTL flash metering: aperture = guide number ÷ distance.
- Guide number 25 in metres at ISO 100 — aperture = GN × √(ISO/100) ÷ distance
Fig. 4 · Front and base: meter coupling lever and its release, lens mounting index, depth-of-field preview lever
Film, focus, double exposures
Frame counter resets to S, two frames before 0, when the back opens
- Type K screen: split-image spot, microprism ring, matte field. Focus with the split image until the two halves line up. Types B and E are interchangeable alternatives.
Fig. 5 · Loading: rewind knob up, cartridge in, leader into the spool, perforations on the sprocket
Fig. 6 · Out of focus · in focus
Specification and neighbours
From the manual's features and specifications